top of page
< Back

Y Branch Connector

Product Models

  • SY-BY21-AB (2 to 1)

  • SY-BY31-AB (3 to 1)

  • SY-BY41-AB (4 to 1)

Standard Ratings

  • IP67: Dust-tight and protected against temporary immersion in water.

  • UL94-V0: Highest fire resistance rating for plastics.

  • UV Resistance: Protected against sunlight damage.

  • Temperature Range: -40°C to +85°C.

  • Certifications: TÜV SÜD, ETL Listed, CE.

Parameter

Value

Rated Voltage

1500V

Test Voltage

6kV (50Hz, 1Min)

Insulation Material

PPO/PC

Contact Material

Copper, tin-plated

Contact Resistance

Less than 0.35 mΩ

Degree of Protection

IP67

Ambient Temperature

-40°C up to +85°C

Certifications

IEC62852 / UL6703

Rated Current by Wire Gauge

  • 2.5mm² (14AWG): 30A

  • 4mm² (12AWG): 35A

  • 6mm² (10AWG): 40A

Packaging Info

  • Carton Dimension: 45cm x 35cm x 24cm

  • Gross Weight: 28kg

  • Quantity: 100 pairs per carton (100 Solar male and 100 Solar female connectors).