InfiniSolar WP Elite Inverter

IP66 certified enclosure
User-friendly HMI LCD design and easy configuration
Dual output for smart load control
Two independent AC power sources connected and switched automatically
Built-in WiFi for mobile monitoring (App is available)
150% unbalanced load support
User-adjustable charging current and voltage
Reserved communication port for BMS (RS485)
5 years warranty
Parallel operation up to 6 units
MODEL DATA:
Maximum PV Input Power: 12000W (8KW) / 15000W (10KW) / 18000W (12KW)
Rated Output Power: 8000W / 10000W / 12000W
Maximum Charging Power: 8000W / 10000W / 12000W
GRID-TIE OPERATION (PV INPUT DC):
Nominal DC Voltage / Maximum DC Voltage: 720 VDC / 900 VDC
Start-up Voltage / Initial Feeding Voltage: 150 VDC / 150 VDC
MPP Voltage Range: 150 VDC to 850 VDC
Full MPP Voltage Range: 400 VDC to 850 VDC (8KW & 12KW) / 420 VDC to 850 VDC (10KW)
Number of MPP Trackers / Maximum Input Current: 2 / A: 15A, B: 15A (8KW); 2 / A: 18A, B: 18A (10KW); 2 / A: 27A, B: 18A (12KW)
GRID-TIE OPERATION (GRID OUTPUT AC):
Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range: 184 - 265 VAC per phase
Nominal Output Current: 11.6 A per phase (8KW) / 14.5 A per phase (10KW) / 17.4 A per phase (12KW)
Power Factor Range: 0.9 lag to 0.9 lead
Maximum Conversion Efficiency (DC/AC): >96%
European Efficiency @ Vnominal: >95%
OFF-GRID OPERATION (AC INPUT):
AC Start-up Voltage / Auto Restart Voltage: 120 - 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range: 170 - 290 VAC per phase
Maximum AC Input Current: 40 A
OFF-GRID OPERATION (PV INPUT DC):
Maximum DC Voltage: 900 VDC
MPP Voltage Range: 150 VDC to 850 VDC
Full MPP Voltage Range: 400 VDC to 850 VDC (8KW & 12KW) / 420 VDC to 850 VDC (10KW)
Number of MPP Trackers / Maximum Input Current: 2 / A: 15A, B: 15A (8KW); 2 / A: 18A, B: 18A (10KW & 12KW)
OFF-GRID OPERATION (BATTERY MODE OUTPUT AC):
Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
Output Waveform: Pure sine wave
Efficiency (DC to AC): >93%
HYBRID OPERATION (PV INPUT DC):
Maximum DC Voltage: 900 VDC
Start-up Voltage / Initial Feeding Voltage: 150 VDC / 150 VDC
MPP Voltage Range: 150 VDC to 850 VDC
Full MPP Voltage Range: 400 VDC to 850 VDC (8KW & 12KW) / 420 VDC to 850 VDC (10KW)
Number of MPP Trackers / Maximum Input Current: 2 / A: 15A, B: 15A (8KW); 2 / A: 18A, B: 18A (10KW & 12KW)
HYBRID OPERATION (GRID OUTPUT AC):
Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
Output Voltage Range: 184 - 265 VAC per phase
Nominal Output Current: 11.6 A per phase (8KW) / 14.5 A per phase (10KW) / 17.4 A per phase (12KW)
HYBRID OPERATION (AC INPUT):
AC Start-up Voltage / Auto Restart Voltage: 120 - 140 VAC per phase / 180 VAC per phase
Acceptable Input Voltage Range: 170 - 290 VAC per phase
Maximum AC Input Current: 40 A
HYBRID OPERATION (BATTERY MODE OUTPUT AC):
Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
Efficiency (DC to AC): >93%
BATTERY & CHARGER:
Battery Voltage Range: 40 to 60 VDC
Maximum Discharging Current: 200 A (8KW) / 220 A (10KW) / 250 A (12KW)
Maximum Charging Current: 160 A (8KW) / 200 A (10KW) / 240 A (12KW)
GENERAL / PHYSICAL / INTERFACE / ENVIRONMENT:
Dimension (D x W x H): 247 x 500 x 650 mm
Net Weight: 50 kgs (8KW & 10KW) / 54 kgs (12KW)
Communication Port: RS-232, RS-485, USB, CAN and Wi-Fi
Intelligent Slot: Optional for SNMP and Modbus cards
Humidity: 0 to 100% RH (Non-condensing)
Operating Temperature: -25 to 60°C (> 45°C power derating)
Altitude: 0 to 1000 m
PROTECTION & CERTIFICATE:
Safety: IEC 62116, IEC 62727, IEC 61683, IEC 62109, IEC 61000-6-2:2019, IEC 61000-6-4:2019, IEC 61000-3-11:2019, EN 61000-3-12: 2011
Grid Connection Standard: NRS097-2-1:2017, VDE-AR-N4105